USCN ELISA Kit for Immunoglobulin G (IgG)
学术研究
~~~高浓度EGFP抗体~~~NQBB血清+生长因子--效果奇佳~~~USCN ELISA Kit~~~Creative Biolabs抗体~~~治疗用抗体~~~核酸萃取仪~~~各式仪器~~~Bilfil各式耗材~~~
首页 经销厂牌 USCN ELISA Kit 【USCN】 ELISA Kit for Immunoglobulin G (IgG)

【USCN】 ELISA Kit for Immunoglobulin G (IgG)

相关连结 Click here

Organism Species Cavia (Guinea pig )





















Product No.                   CEA544Gu

Organism Species         Cavia (Guinea pig )            Same name, Different species.

Test Method                  Competitive Inhibition

Assay Length                2h

Detection Range           1.23-100ug/mL

Sensitivity                     The minimum detectable dose of this kit is typically less than 0.48ug/mL.

Sample Type                 Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Download                      Instruction Manual

UOM                             48T   96T   96T*5   96T*10   96T*100

 
ad016917b07a3e5d571c6367afde061b.jpg7461fae71a784c9bd1335facf15595f7.jpg


Specificity of the ELISA Kit for Immunoglobulin G (IgG)

This assay has high sensitivity and excellent specificity for detection of Immunoglobulin G (IgG).
No significant cross-reactivity or interference between Immunoglobulin G (IgG) and analogues was observed.


Recovery of the ELISA Kit for Immunoglobulin G (IgG)

Matrices listed below were spiked with certain level of recombinantImmunoglobulin G (IgG) and the recovery rates were calculated by comparing the measured value to the expected amount of Immunoglobulin G (IgG) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)86-10195
EDTA plasma(n=5)90-10297
heparin plasma(n=5)84-9187


Precision of the ELISA Kit for Immunoglobulin G (IgG)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Immunoglobulin G (IgG) were tested 20 times on one plate, respectively. 
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Immunoglobulin G (IgG) were tested on 3 different plates, 8 replicates in each plate. 
CV(%) = SD/meanX100 
Intra-Assay: CV<10% 
Inter-Assay: CV<12% 


Linearity of the ELISA Kit for Immunoglobulin G (IgG)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Immunoglobulin G (IgG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)79-96%80-98%86-105%89-101%
EDTA plasma(n=5)86-99%95-102%86-95%93-101%
heparin plasma(n=5)84-101%92-101%78-96%87-104%


Stability of the ELISA Kit for Immunoglobulin G (IgG)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.


Assay procedure summary of the ELISA Kit for Immunoglobulin G (IgG)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well. 
    And then add 50µL prepared Detection Reagent A immediately. 
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 5 times;
4. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
5. Add 50µL Stop Solution. Read at 450 nm immediately.


Test principle of the ELISA Kit for Immunoglobulin G (IgG)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Immunoglobulin G (IgG) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Immunoglobulin G (IgG) in the samples is then determined by comparing the O.D. of the samples to the standard curve.


Related products

Catalog No.Organism species: Cavia (Guinea pig )Applications (RESEARCH USE ONLY!)
NPA544Gu01Native Immunoglobulin G (IgG)Positive Control; Immunogen; SDS-PAGE; WB.
PAA544Gu01Polyclonal Antibody to Immunoglobulin G (IgG)WB; IHC; ICC; IP.
SAA544Gu09HRP-Linked Rabbit Anti-Cavia IgG Polyclonal AntibodyWB; IHC; ICC.
SAA544Gu07Biotin-Linked Rabbit Anti-Cavia IgG Polyclonal AntibodyWB; IHC; ICC.
SAA544Gu08FITC-Linked Rabbit Anti-Cavia IgG Polyclonal AntibodyWB; IHC; ICC; IF.
MAA544Gu21Monoclonal Antibody to Immunoglobulin G (IgG)WB; IHC; ICC; IP.
CEA544GuELISA Kit for Immunoglobulin G (IgG)Enzyme-linked immunosorbent assay for Antigen Detection.
CCA544GuCLIA Kit for Immunoglobulin G (IgG)Chemiluminescent immunoassay for Antigen Detection.
KSA544Gu11ELISA Kit DIY Materials for Immunoglobulin G (IgG)Main materials for "Do It (ELISA Kit) Yourself".

 


订阅商品讯息订阅商品讯息 Copyright © 2016 GenLabBiotech Co.,Ltd. All rights reserved.
Powered by www.url.com.tw